【 Flow Meter 】 Fuel Flow and Density Meter FDM Series

Not just volume, but density and mass flow also now measurable in real-time

02_FDMシリーズ_1
02_FDMシリーズ_1 
 
02_FDMシリーズ_3 

Various possible measurements to obtain the detailed fuel flow by inputting the signals from a volumetric flow sensor, a density sensor, a temperature sensor, and a pressure sensor.

A multitude of measurements: instantaneous flow/average flow of total time/average flow of total time per interval/total flow/total flow per interval/total time/total time per interval/instantaneous density/converted density/instantaneous temperature/instantaneous pressure.

Features

  • Real-time simultaneous measurement
    Possible instantaneous and synchronized display and output of instantaneous flow, density, mass (converted), temperature, and pressure data.
  • High-speed instantaneous flow and pressure measurement
    0.5ms high-speed refresh time for the analog output of both instantaneous flow and pressure. And setting of a moving average in units of 0.5ms also possible. Rapid fluctuations in flow and pressure can be captured.
    (Note) FDM-720 is for 1ms.
  • High-resolution measurement
    With a high measuring resolution, detailed measurements can be made during dling, at low rotational speeds and low loads, and of the variation in engine torque.
    ●FDS-1213+FDM-700/FDM-720: 0.0005mL
    ●FDS-1214+FDM-700/FDM-720: 0.0055mL

Introduction to Functions

A multitude of measurements can be realized with the input of signals from the fuel flow and density detector FDS series or the fuel flow detector FS series, and from the density detector DM-200.

Possible simultaneous measurement of instantaneous flow, by mass conversion, total flow, total time, density, temperature, pressure, and so on.

FDS_FDM_Configuration_diagram_2

Specification

FDM-700 FDM-720
Arithmetic
Connection detector Fuel flow and density detector
Fuel flow detector
Density detector
Inter-channel calculation No Yes
Temperature correction Correction of the volume flow to standard temperature using the detected temperature
Mass conversion Calculation of the detected volume flow and density
Display
Display Color graphic LCD (resolution 480*272)
Measuring screen display format Selection from a display of 2, 4, 6, 12 items
Update cycle According to a setting of 1s for the density and temperature, 0.1s for the time and total flow, and 0.1 to 10s for the instantaneous flow and pressure
Memory for displayed items The content of the measuring screen display is saved in 3 different patterns
Items (units) Selectable items and units
(maximum display of 12 of the following items)
Instantaneous flow/average flow of total time/average flow of total time per interval
(mL/s, g/s, mL/min, g/min, L/h, kg/h)
Total flow/total flow per interval (mL, g, L, kg)
Total time/total time per interval (s, min)
Instantaneous density/converted density (g/cm3)
Instantaneous temperature (°C), instantaneous pressure (kPa)
Signal input
Number of inputs
Density and flow detector 1 input 2 inputs
Integrated external control 1 input (start-stop switch for connection)
Input functions START/STOP/HOLD/STOP/MONI
Analog output
Number of outputs 8 outputs
(possible selection of 8 of the following items, and scaling possible for a single item)
Connector BNC receptacle
Items Instantaneous flow/average flow of total time/average flow of total time per interval/
Total flow/total flow per interval/total time/total time per interval/
Instantaneous density/converted density/instantaneous temperature/instantaneous pressure
D/A conversion resolution 16bit (±10.5V)
Scaling All items variable from zero to full scale
Output range ±10V (load of 4.7kΩ or more)
Accuracy ±0.1%F.S.(@23°C±5°C)
Refresh time
Instantaneous flow and pressure Fixed at 0.5ms Fixed at 1ms
Instantaneous density and temperature Fixed at 1s
Measurement over an interval For every HOLD (including automatic input) and STOP input
Pulse output
Number of outputs 4 outputs
Connector BNC receptacle
Items
Pulse output in integrated units P OUT1 P OUT1,2
Output during integration P OUT2 P OUT1,2
Flow sensor phase A output P OUT3 P OUT3,4
Flow sensor phase B output P OUT4 P OUT3,4
Pulse output resolution in integrated units 0.001/0.01/0.1/1mL(g)/P
Output during integration 5V output at START
Flow sensor A/B phase output Flow sensor phase A or phase B signal output built in to the detector
Output range 0-5V logic signal (±4mA/ch output current)
Stopping condition for the integrated measurement
Stopped manually From the starting operation for the integrated measurement to the stopping operation
Integration time From the starting operation for the integrated measurement up until the total integration time has been reached
Total flow From the starting operation for the integrated measurement up until the total integrated flow has been reached
Integrated measurement functions
One-time measurement A one-time measurement from the starting operation for the integrated measurement up until the integrated measurement stopping condition is satisfied
Measurement over an interval Over the interval from the starting operation for the integrated measurement to a HOLD or STOP input
Continuous measurement After the integrated measurement stopping condition has been established following the starting operation for the measurement, integrated measurement is repeated once again, and continues up until it is stopped manually
Clock
Functions The current time is displayed in the 24-hour format
Data memory
Saved items Individual measured values, saved time, and types of saved events
Save Automatically saved on a HOLD or STOP
Memory capacity 100 addresses with automatic increment, returning to 1 following 100
RS-232C interface
Functions Reading out measured values, and reading and writing settings
Connector D-Sub9pin male
General specification
Supplied power sources DC9 to 32V (20W or less), and attached AC adaptor
Electrical insulation Detector input – analog output, pulse output, communication – supplied power sources
Operating temperature and humidity range 0 to 40°C, 85%RH or less (with no condensation)
External dimensions See the external dimensions diagram
Weight Approx. 1.7kg