【 Twin Digital Panel Meter 】【 Flow Meter 】 Flow Meter TFW-200/TFM-200

Highly-functional twin digital panel meter

パネルメータ

■TFW-200 Instantaneous and total flow meter
  With all the functions necessary as a meter for measuring fuel flow

■TFM-200 Instantaneous flow meter
 Simultaneous measurement with two flow sensors (A, B)

 A high-precision, highly-functional digital panel meter with the capabilities of a measuring instrument that is specialized for flow rate    Display consisting of 6-digit and 13-digit, two-level, high brightness LCD display (red and green)      Compatible for CAN output     Possible simultaneous output of two analog channels

Features

  • The first panel meter that has been used for CAN data output (option)
  • 6-digit and 13-digit, two-level, high brightness LCD display (red and green). You can choose the display color.
  • A multitude of options (analog output/BCD output/CAN output/contact output/RS232 communication/RS485 communication/USB communication)

Introduction to Functions

【High-performance functions】
The functions and performance of the flow rate meter have been incorporated into the panel meter. Analog output is at a high speed of 1ms.
And you can choose from a multitude of output options to use

  • Instantaneous flow and total flow can be measured simultaneously
  • As well as the real total flow, you can also measure the average flow over any given period
  • Both flow sensors (A, B) can be measured at the same time, and the display and analog signal for each can be output as desired
  • The combinations A+B, A-B, and the average flow can also be measured as either the instantaneous or the total flow
  • An auto-repeat measurement is possible in which integration commences when “Start” is entered, and the display and output refreshed after a set time has elapsed, and this then repeated until “Stop” is entered. 

The model configuration of the TFW-200 and TFM-200 is shown in the figure below.
When option “No” was selected the model configuration is left-justified.
Multiple options of the same option group cannot be selected.
Two types of output can be selected from among digital output, contact output, and communication.

 04_TFW-200_TFM-200

Specification

Model TFW-200 TFM-200
Name Instantaneous and total flow meter Instantaneous flow meter
Arithmetic
Input operations A/AB (reversible)/A+B/A-B/AB average
 Instantaneous measurement Measurement method Periodic calculation method (with function for predicting deceleration)
Measurement clock 20MHz
 Total measurement Measurement method Scaling integration
Integration method Free/timer stop/timer repeat
 Operation key 5 points Separate function at measurement/setting
 Memory Memory element Non-volatile memory
Memory content Setting values and total flow Setting values
Display
 Display LCD negative, backlight
 Main display Display items Instantaneous flow
Display color, character height, number of digits Switching between red and green backlight, 14.2mm, 6 digits + polarity (-)
 Sub-display Display items Total flow (TFW-200 only)/comparator setting values/Instantaneous flow A – B/OFF
Display color, character height, number of digits Switching between red and green backlight, 6.5mm, 13 digits + polarity (-) at 2 points
 Status display Display color Switching between red and green backlight
 Instantaneous measurement Refresh time 0.1 to 9.9s
Moving average 1 to 99
Signal input (sensor input)
 Number of inputs 2 inputs
 Types of input signal (CH) Single-phase (2ch) / UP/DOWN (1ch) / A/B 2-phase signal (1ch) switching
 Maximum input frequency Single-phase, UP/DOWN signal 100kHz
A/B 2-phase signal 60kHz
 Minimum input frequency 0.005Hz (only for measurement of instantaneous flow)
 Frequency division (pulse average) Signal A only, 1 to 999
Signal input (sensor input) (0) General purpose
 Input level AC (zero-cross) signal ±200mV to ±30V, LPF switching
Signal A
Logic signal H level 3.9V or more, L level 1V or less (voltage resistance ±30V)
Others Pull-up/pull-down switching
 Power supply for sensor Voltage and maximum current DC12V±10%, 100mA
 External control input Number of points 2 points
Signal type Contact/TTL (minimum pulse width 5ms)
Items Start/Stop/Reset/Hold switching
Analog output
 Refresh time 0.001 to 9.999s
 D/A conversion 16bit
Analog output (V) General purpose (1CH)
 Number of outputs 1 output
 Output items Instantaneous flow/total flow Instantaneous flow
 Output range Voltage output range ±10/0-10/0-5/1-5 V (load of 4.7kΩ or more)
Current output range 4-20mA (load of 560Ω or less)
 Accuracy Voltage output ±0.1%F.S. or less/current output ±0.2% F.S. or less (23)/temperature variation ±200ppm/ or less
Analog output (W) Voltage (2CH)
  Number of outputs 2 outputs
 Output items Instantaneous flow/total flow Instantaneous flow
 Output range Voltage output range ±10V (load of 4.7kΩ or more)
 Accuracy Voltage output ±0.1%F.S. or less (23ºC)/temperature variation ±200ppm/ºC or less
Contact output (C) Contact output (photo MOS relay), (O) Contact output (open collector)
 Number of outputs 4 outputs
 Refresh time Analog synchronization/display synchronization switching
  Output items Comparator/unit pulse switching
 Unit pulse rate, maximum frequency 0.1 to 9999.9mL/P, 1kHz
 Output circuit (C) Photo MOS relay Maximum load voltage (peak AC/DC) 350V, continuous load current (peak AC/DC) 80mA, output ON resistance 35Ω (typical)
(O) Open collector  NPN open collector, maximum load voltage 30V, maximum load current 15mA
Communication (4) RS-485 (2) RS-232 (U) USB
 Communication format Serial communication (4) RS-485/(2) RS-232/(U) USB
Communication speed 9.6k/19.2k/38.4k bps
Data length 7/8 bit
Parity bit Null/even/odd
Stop bit 1/2 bit
Character code ASCII
Digital output
 Output items Instantaneous flow/total flow Instantaneous flow
 Refresh time Analog synchronization/display synchronization switching
Digital output (T) BCD output (TTL), (P) BCD output (open collector)
 Number of output digits 6 digits + polarity
  Output circuit (T) TTL Output voltage 0-5V (output current ± 100mA, but ± 4mA/ch)
(P) Open collector  NPN open collector, maximum load voltage 30V, maximum load current 20mA/ch
Digital output (N) CAN
  Output circuit CAN2.0B compliance High-Speed CAN (ISO11898-2)
Communication speed 1Mbps/500kbps/250kbps/125kbps
Data format Little endian/Big endian
ID length Standard 11bit/Extended 29bit
Data format Signed long (4 bytes)
Output refresh time Digital output refresh time/1/2/5/10ms
General specification
 Supplied power sources (A) Power supply (AC) AC100 to 240V ±10% (50/60Hz), (100V, 18VA or less, 240V, 24VA or less)
(D) Power supply (DC) DC12 to 24V ±10% (10W or less)
 Electrical insulation Insulation range Sensor input – analog output – contact output – communication and digital output – supplied power sources
 Protective structure Front panel IP66
 Operating temperature and humidity range 0 to 50, 85%RH or less (with no condensation)
 External dimensions, Weight W: 96 H: 48 D: 100 (D: 93 inside part)
Approx. 230g (when equipped with all options)